-
rhode alain,FranceIt is very nice to work with real professionals. They are attentive and responsive.
-
Alejandro Gidi,Mexicoexcellent communication from seller. Ms Daisy was clear and on time, product was shipped properly packaged. A+
-
Sergey Shapotkin,Russian Federeverything fine
SC Apc G657A2 4.8mm 1550nm Fiber Optic Cable Assembly
Place of Origin | Shanghai China |
---|---|
Brand Name | Yogel or OEM |
Certification | ISO9000,original |
Model Number | MDU/FTTH Drop cable |
Minimum Order Quantity | 1 |
Price | Negotiate |
Packaging Details | 100 pieces /carton box |
Delivery Time | 3-5 days after despoit |
Payment Terms | Western Union, MoneyGram, T/T, L/C |
Supply Ability | 10000 pcs/ month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | 4.8mm Double-ended SC Apc Simplex G657A2 MDU FTTH Round Drop Cable Assemblies Patch Cord | Application | Outdoor, FTTH Fiber Network, Telecommunication, Data Center/FTTX/LAN And WAN/CATV Network/Telecommunications Network, RF Device |
---|---|---|---|
Insertion Loss | Typ. ≤0.15 DB, Max. ≤0.30 DB | Return Loss | ≥60dB |
Repeatability | ≤0.10 DB | Changeability | ≤0.20 DB |
Color | Black Or OEM | Cable Jacket | OFNR, LSZH, OFNP |
Highlight | 4.8mm Fiber Optic Cable Assembly,1310nm Fiber Optic Cable Assembly,SC Apc fiber optic assemblies |
4.8mm Double-ended SC Apc Simplex G657A2 MDU FTTH Round Drop Cable Assemblies Patch Cord
Description
YOGEL single-mode SC Angled Indoor and Indoor/Outdoor MDU Drop Assemblies are designed to meet stringent performance requirements of the latest FTTH (Fiber to the Home) applications. Bend insensitive fiber reduces macro-bending attenuation when routing the drops in tight environments and the SC angled connector guarantees the high-performance return loss required of video signals. Availability in both compact 3.0mm and rugged 4.8 mm varieties allows for multiple installation scenarios. Assemblies are tested and qualified to Telcordia GR-326, Issue 3 requirements and meet all EIA.TIA 455-3 (FOCIS 3) interface standards for SC connectors.
Features
Low insertion loss & High return loss
Ceramic ferrule utilized for precision fiber alignment
Connector housings are color coded (Green) for APC identification and -65 dB return loss
Keyed push-pull latching mechanism
Connectors compliant with Telcordia GR-326
Cable compliant with Telcordia GR-409
Mechanical performance compliant with IEC 61754-4
RoHS compliant - Riser, Plenum, and LSZH rated cables available
Applications
Building interconnections (campus LAN)
Connector end in optical distribution boxes and termination boxes
Trunk lines direct to telecommunications closet
Cross-connect in outdoor closet
Distribution connect in central office ODF / MDF
Links between NAPs and ONUs or Nodes
Multi-Dwelling Unit (MDU) drop cables for FTTH solutions, CATV Video Systems, LAN Networks
Specifications
Item | Parameter | ||
Single Mode | |||
PC | UPC | APC | |
Test wavelength | 1310/1550nm | ||
Insertion loss | Typ. ≤0.15 dB, Max. ≤0.30 dB | ||
Return Loss | ≥45 dB | ≥50 dB | ≥60 dB |
Repeatability | ≤0.10 dB | ||
Changeability | ≤0.20 dB | ||
Durability (1000 Mating) | ≤0.20 dB | ||
Operation temperature | -40 ~ +80℃ | ||
Storage temperature | -40 ~ +85℃ | ||
Connector end | SC/UPC, SC/APC | ||
Cable jacket | OFNR, LSZH, OFNP | ||
Cable diameter | 3.0mm, 4.8mm | ||
Fiber count | Simplex | ||
Fiber type | Single Mode: G. 657A2 | ||
Cable length | 0.5m, 1m, 2m, 5m, 10m, 20m, 25m, etc. | ||
Fiber brand | Corning, YOFC, TFO | ||
Fire resistant | IEC 60794-2-30 | ||
Standards Compliant | ROHS, IEC, GR-326 |
Cable Components
Order Information
Connector End A - Connector End B,
Cable Jacket, Cable Diameter, Fiber Count, Fiber Type, Cable length
Example:
SC/UPC-SC/APC,
LSZH, 3.0mm, Simplex, G.657A2, 30 meters
Round Drop Cable patch cord